Insulation & Earth Ground

Fluke 1577

Fluke 1577 Insulation Multimeter

Insulation test voltages 500V, 1000V
Insulation test: 0.1 MOhms to 600 MOhms
Auto discharge of capacitive voltage
AC/DC Voltage
DC millivolts
AC/DC milliamps
Resistance (0.1 Ohms to 50 MOhms )
Three-year warranty
Remote probe, test leads, alligator clips
Rugged, utility hard case
Auto power off to save battery power
True-rms
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
CAT III 100V, CAT IV 600V measurement category

   

Fluke 1587FC

Fluke 1587FC Insulation Multimeter

Insulation test voltages 50V, 100V, 250V, 500V, 1000V

Fluke Connect Measurement App for your Apple or Android device
Insulation test: 0.01 MOhms to 2.0 GOhms
Low pass filter (for work on VSD’s)
AC/DC Voltage
DC millivolts
AC/DC milliamps
Resistance (0.1 Ohms to 50 MOhms )
Continuity
Three-year warranty
Remote probe, test leads, alligator clips
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
CAT III 100V, CAT IV 600V measurement category

   

Fluke 1587 FC 62max kit

Fluke 1587 KIT/62MAX+ FC

Package Includes :
Fluke 1587FC Insulation Multimeter
Fluke 62MAX Infared Thermometer
Fluke i400 Current Clamp

Fluke 1587mdt fc kit

Fluke 1587/MDT FC

Package Includes :
Fluke 1587FC Insulation Multimeter
Fluke 62MAX+ Infared Thermometer
Fluke i400 Current Clamp

Fluke 9040 Phase Rotation Indicator

Fluke 1503

Fluke 1503 Insulation Tester

Insulation test range: 0.1 Mohm to 2000 Mohm
Insulation test voltages:500 V, 1000 V
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
AC/DC voltage: 0.1 V to 600 V
200 mA Continuity
Resistance
CAT IV 600 V overvoltage category rating for added user protection
Remote probe, test leads, probes and alligator clips included with each tester
Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
Four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests
One year warranty

   

Fluke 1507

Fluke 1507 Insulation Tester

Insulation test range:0.01 Mohm to 10 Gohm
Insulation test voltages:50 V, 100 V, 250 V, 500 V, 1000 V
Live circuit detection prevents insulation test if voltage > 30 V is detected for added user protection
Auto-discharge of capacitive voltage for added user protection
AC/DC voltage: 0.1 V to 600 V
200 mA Continuity
Resistance: 0.01 ohm to 20.00 kohm
CAT IV 600 V overvoltage category rating for added user protection
Remote probe, test leads, probes and alligator clips included with each tester
Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
Four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests
One year warranty

   

fluke 1550c large image

Fluke 1550C 5kV Insulation Tester

Test voltages up to 5 kV provides solutions for most applications
CAT III 1000 V, CAT IV 600 V safety rating
Voltage breakdown detection alerts the user that voltage is present and gives the voltage
reading up to 600 V ac or dc for increased user safety
Selectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above
1000 V
Long battery life gives the user over 750 tests between charges
Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
Capacitance and leakage current measurement
Ramp function for breakdown testing
Resistance measurements up to 1Tohm
3-year warranty

      

Fluke 1555C

Fluke 1555C 10kV Insulation Tester

Test voltages up to 10 kV provides solutions for most applications
CAT III 1000 V, CAT IV 600 V safety rating
Voltage breakdown detection alerts the user that voltage is present and gives the voltage reading up to 600 V ac or dc for increased user safety
Selectable test voltages in 50 V steps from 250 to 1000 V, and 100 V steps above 1000 V
Measurements can be stored in up to 99 memory locations, with each location assigned a unique, user defined, label for easy recall
Long battery life gives the user over 750 tests between charges
Automatic calculation of Dielectric Absorption (DAR) and Polarization Index (PI) with no additional setup
Resistance measurements up to 2Tohm
3-year warranty

      

Fluke 1550C kit

Fluke 1550C Kit

Package Includes :
Fluke 1550C 5kV Insulation Tester
Soft carrying case
NIST Traceable Certificate of Calibration
Additional Ruggedized Croc Clips

Fluke View Forms Software

      

Fluke 1550C kit

Fluke 1555C Kit

Package Includes :
Fluke 1555C 10kV Insulation Tester
Soft Carrying Case
NIST Traceable Certificate of Calibration
Additional Ruggedized Croc Clips

Fluke View Forms Software

      

Fluke 1623-2

Fluke 1623-2 Earth Ground Tester GEO

One-button measurement concept
3- and 4-pole earth ground measurement
2-pole resistance measurement AC
Selective testing, no disconnection of ground conductor (1 clamp)
Stakeless testing, quick ground loop testing (2 clamps)

   

Fluke 1625-2

Fluke 1625-2 Earth Ground Tester GEO

3- and 4-pole earth ground measurement
4-Pole soil resistivity testing
2-pole resistance measurement AC
2- and 4-pole resistance measurement DC
Selective testing, no disconnection of ground conductor (1 clamp)
Stakeless testing, quick ground loop testing (2 clamps)
Automatic frequency control (AFC) (94 to 128 Hz)
Programmable limits, settings

   

Fluke 1623-2 kit

Fluke 1625-2 /Kit

Package Includes :
Fluke 1625-2 Earth Ground Tester (GEO)
Stake/Reel set 4 Pole
Selective/Stakeless Clamp Set

   

Fluke 1623-2 kit Fluke 1623-2/Kit

Package Includes :
Fluke 1623-2 Earth Ground Tester (GEO)
Stake Reel Set 4 Pole
Selective Stakeless Clamp Set

   

Fluke 1630-2 fc

Fluke 1630-2 FC Earth Ground Clampmeter

A wide ground loop resistance range, from 0.025 Ohms to1500 Ohms , to satisfy all requirements
Large jaw opening of 35 mm (1.38 in) for tests on ground conductors and/or equipotential bus bars
Measurement of ground leakage current, from 0.2 mA to 1000 mA, without needing to disconnect – ideal for system troubleshooting
Wide ac current measurement range from 0.2 A to 30 A allows one instrument for multiple applications
User-defined HI / LO Alarm limits, for rapid measurement evaluation
Handy `display hold` button for capturing readings in hard-to-reach places
Time saving memory function automatically records and stores measured values
Automatic self calibration ensures correct measurement every time
Overload protection: 200 A
Carrying case and resistance test loop included
8 hours battery life (continuous operation)