Intrinsically Safe

image16=2

Fluke 28ii Ex Digital Multimeter

4-1/2 digit mode for precise measurements (20,000 counts)

True-rms ac voltage and current for accurate measurement on nonlinear signals

True-rms ac voltage and current for accurate measurement on nonlinear signals

Low pass filter ensures accurate voltage and frequency measurements on variable speed motor drives

Frequency to 200 kHz and % duty cycle to help you diagnose VSDs and switching power supplies

Resistance, continuity and diode test

10,000 μF capacitance range for components and motor caps

Conductance measurements for high resistance o r leakage tests

Min/Max-Average and Peak capture to record transients and variations automatically

Relative mode to remove test lead interference on resistance measurements

Auto and manual ranging for maximum flexibility

Input Alert protects you by chirping and flashing

IP 67 meter – Water proof, dust proof and 3m drop proof

   

Fluke 177IS Intrinsically Safe Digital Multimeter

Units Individually made Intrinsically safe by a local South African Laboratory, Engraved with details and Certification Supplied

Manual and automatic ranging

Display Hold and Auto Hold

Frequency and capacitance measurements

Resistance, continuity and diode measurements

Min-max-average recording

Closed case calibration through front panel

Ergonomic case with integrated protective holster

Safety conformance : All inputs are protected to IEN61010-1 CAT IV 600 V/CAT III 1000 V. UL, CSA, TÜV listed and VDE Pending

   

image17-3

Fluke 725 Ex Multi function process calibrator

ATEX II 1 G Ex ia IIB 171 C KEMA 04ATEX 1303X

I.S. Class I, Division 1 Groups B-D, 171 C compliance

Measure Volts dc, mA, RTDs, thermocouples, frequency and ohms

Source or simulate Volts dc, mA, RTDs, thermocouples, frequency and ohms

Two channel simultaneous source and measure capability for calibration of transmitters

Power transmitters with internal loop supply

Store frequently-used test setups for later use

Pressure measurement to 3,000 psi/200 bar, calibrate pressure transmitters and I/P devices

Pressure switch test function to capture set, reset and deadband values

Compact size and weight

Simple, push-button user interfaceRugged and reliable, for field

   

image18-4

Fluke 707 Ex Loop Calibrator

Large display and simple, quick-click push rotary button for easy one-handed operation

Simultaneous mA and % readout for quick, easy, interpretation of readings.

mA accuracy of 0.015%, superior to other loop calibrators

1 A resolution for mA source, simulate and measure

Push button with 25% steps for fast, easy linearity checks

0-100% “span check” for fast confirmation of zero and span

Selectable slow ramp, fast ramp, and step ramp

Internal loop supply, so you can power and read a transmitter at the same time

Measures Vdc to 28 V

Single 9 V battery that is easily changed

0-20 mA or 4-20 mA default start up modes 

Innovative output adjustment dial with 1 A and 100 A resolution

HART compatible resistance

   

image19-5

Fluke 718 Ex Pressure Calibrator

ATEX II

1G Ex ia IIC T4 Compliant.

Built-in pressure / vacuum hand pump, with fine adjust vernier and bleed valve.

30, 100, and 300 psi ranges (2, 7, and 20 bar)

Pressure measurement to 0.05% of full span, using an internal

pressure sensor.Pressure measurement to 200 bar using any intrinsically safe Fluke 700PEx Pressure Modules.

Wide range of selectable measurement units for pressure.

Current measurement with 0.02% accuracy and 0.001 mA resolution.

Pressure switch test function.

Min-Max Hold functions.

Compact size and weight.

Simple, push-button user interface.

Rugged and reliable, ideal for field

   

Fluke 568 Ex Intrinsically Safe Infrared Thermometer

Meets intrinsically safe certifications in Class I Div 1 and Div 2 or Zone 1 and 2 hazardous environments from recognized safety agencies around the world

Measure -40°C to 800°C / -40°F to 1472°F

Conductive Case for carrying the IR thermometer safely into hazardous area

Easily access advanced features with the soft-key buttons and graphical display

Measure small objects from further away, with a distance-to-spot ratio of 50:1

Compatible with mini-connector K-type thermocouple (KTC) probe

Confidently measure a wide variety of surfaces with the adjustable emissivity feature, including a built-in material table

Capture up to 99 points of data

Confidently troubleshoot equipment with ±1% measurement accuracy

Two-year warranty

   

Fluke 721 Ex Intrinsically Safe Pressure Calibrator

Intrinsically Safe (721Ex version only) – IECEx and Atex Ex ia IIB T3 Gb (Zone 1)

Ideal for gas flow calibration (custody transfer) applications

Two isolated, stainless steel, pressure sensors with 0.025 % accuracy

Pt100 RTD input for temperature measurement, (probe optional)

Switch test on both pressure inputs

Pressure displayed in the user’s choice of 19 engineering units

Large backlit graphic display can display up to three inputs simultaneously

Store five instrument setups for recall and use

   

Fluke 1551A/1552A Intrinsically Safe “Stik” Thermometer

Accuracy of ±0.05°C (±0.09°F) over full range

Intrinsically safe (ATEX and IECEx compliant)

Two models to choose from (-50°C to 160°C or -80°C to 300°C)

User-configurable temperature Trend/Stability indicator

Display temperature in °C or °F

Optional data logging to internal memory

300-hour battery life

Percent battery-life and low-battery indicator

NVLAP-accredited, NIST-traceable calibration included

   

Fluke 700G Series Intrinsically Safe Pressure Gauges

Ranging from 20mbar to 690bar

Bright backlit display for easy viewing of pressure measurements

Rugged, durable design with protective holster

High accuracy, 0.05% total measurement uncertainty for one year

Combined with either the 700PTPK pneumatic pump kit or the 700HTPK hydraulic pump kit for a complete measurement and testing solution

Demand measurement logging to a PC or to internal memory with 700G/TRACK software

Work safely in classified areas known to include explosive gasses;CSA: Class 1, Div2, Groups A-D rating ATEX: rating II 3 G Ex nA IIB T6 Three-year warranty promises long term value for the investment